Midea MARS Mono R290 MHS-SVC50-RN7L-B Heat Pump | MIDEA.BG | Midea.bg
New Midea MARS Mono R290 MHS-SVC50-RN7L-B Heat Pump

Midea MARS Mono R290 MHS-SVC50-RN7L-B Heat Pump

  • Series: MARS;
  • Cooling SEER: 4.70;
  • Heating SCOP: 4.50;
  • Warranty: 36 months
Find the nearest dealer

Functions and extras:

    Technical specifications for Three-phase Midea Mars R290 Mono MHS-SVC50-RN7L-B Heat Pump
    Model nameMHS-SVC50-RN7L-B
    Cooling (A35/W7)CapacitykW50
    InputkW15.15
    EER3.30
    Cooling (A35/W18)CapacitykW50
    InputkW10.42
    EER4.80
    Heating (A7/W35)CapacitykW50
    InputkW10.64
    COP4.70
    Heating (A7/W45)CapacitykW50
    InputkW13.16
    COP3.80
    Heating (A7/W55)CapacitykW50
    InputkW15.15
    COP3.30

    Heating (A7/W65)

    CapacitykW50
    InputkW17.86
    COP2.80
    Heating (A2/W35)
    (Excluding defrosting cycle)
    CapacitykW54
    InputkW15.88
    COP3.40
    Heating (A2/W35)
    (Including defrosting cycle)
    CapacitykW51
    InputkW15.46
    COP3.30
    Heating (A2/W45)
    (Excluding defrosting cycle)
    CapacitykW55
    InputkW18.97
    COP2.90
    Heating (A2/W45)
    (Including defrosting cycle)
    CapacitykW52
    InputkW19.26
    COP2.70
    Heating (A2/W55)
    (Excluding defrosting cycle)
    CapacitykW56
    InputkW21.96
    COP2.55
    Heating (A2/W55)
    (Including defrosting cycle)
    CapacitykW52
    InputkW21.22
    COP2.45
    Heating (A7/W35)
    (Excluding defrosting cycle)
    CapacitykW54
    InputkW19.29
    COP2.80
    Heating (A7/W35)
    (Including defrosting cycle)
    CapacitykW50
    InputkW18.87
    COP2.65
    Heating (A7/W45)
    (Excluding defrosting cycle)
    CapacitykW54
    InputkW22.98
    COP2.35
    Heating (A7/W45)
    (Including defrosting cycle)
    CapacitykW50
    InputkW22.22
    COP2.25
    Heating (A7/W55)
    (Excluding defrosting cycle)
    CapacitykW56
    InputkW27.32
    COP2.05
    Heating (A7/W55)
    (Including defrosting cycle)
    CapacitykW50
    InputkW25.64
    COP1.95
    SCOPWarmer climate35⁰C6.27
    55⁰C4.81
    Average climate35⁰C4.70
    55⁰C3.90
    Colder climate35⁰C3.68
    55⁰C3.28
    TOCA (Total Over-Current Amps.)A70
    MOP (Maximum Overcurrent Protector)A80
    MCA (Minimum Circuit Amps)A60
    MFA (Maximum Fuse Amps)A80
    CompressorTypeScroll
    Poles4 полюсa
    Speed rangerps14 ~ 130
    Capacity (60rps)kW18.44
    Input (60rps)kW5.590
    Max. heating frequencyHz14 ~ 130
    Max. cooling frequencyHz14 ~ 130
    RLAA15.45
    FanMotor typeDC безчетков мотор
    Number of fans2
    Air flowm3/h28670
    Rated Motor inputkW0.92
    FLA (Full Load Amps)A4
    Air side heat exchangerNumber of rows3
    Number of circuits19
    RefrigerantType (GWP)R290 (0.02)
    Charged volumekg2.8 x 2
    Throttle typeEEV
    Sound Power LevelHeating (A7/W35)dB(A)86.4
    Heating (max)dB(A)86.7
    Heating (silence mode 1)dB(A)75.9
    Heating (silence mode 2)dB(A)72.6
    Cooling (A35/W7)dB(A)84.8
    Cooling (max)dB(A)84.4
    Cooling (silence mode 1)dB(A)75.1
    Cooling (silence mode 2)dB(A)72
    Sound Pressure LevelHeating (A7/W35)dB(A)69.5
    Heating (max)dB(A)70.2
    Heating (silence mode 1)dB(A)59.3
    Heating (silence mode 2)dB(A)55.4
    Cooling (A35/W7)dB(A)67.3
    Cooling (max)dB(A)67.5
    Cooling (silence mode 1)dB(A)56.7
    Cooling (silence mode 2)dB(A)53.8
    Unit dimension (W×D×H)mm2000 × 960 × 1880
    Packing dimension (W×D×H)mm2085 × 1030 × 2050
    Net weightkg560
    Gross weightkg585
    Connection dimensionWater sidemmDN50
    Connection methodWater sidemmСвързване чрез рингове
    Outdoor air
    temperature range
    Cooling°C-15 ~ 48
    Heating°C-25 ~ 43
    DHW°C-25 ~ 43
    Water side heat
    exchanger
    TypeПластина
    Safety valveMPamm0.6
    Flow switchm3/hmm1.2
    Water flow rangem3/hmm1.8 ~ 14.4
    Water outlet
    temperature setting
    range
    Cooling°C5 ~ 25 (-5 ~ 25)1
    Heating°C25 ~ 70 (25 ~ 85)2
    DHW (танк)°C20 ~ 70 (20 ~ 80)2
    Seasonal space heating
    energy efficiency class
    Water outlet at 35⁰Cηs177.00%
    classA+++
    Water outlet at 55⁰Cηs147.40%
    classA++
    SCOPWater outlet at 35⁰C/4.50
    Water outlet at 55⁰C/3.76
    Seasonal space cooling
    energy efficiency class
    Water outlet at 7⁰Cηs185.00%
    Water outlet at 18⁰Cηs257.00%
    SEERWater outlet at 7⁰C/4.70
    Water outlet at 18⁰C/6.50

    Note:

    1. The above data test reference standard EN14511; EN14825; EN50564; EN 12102; (EU) No:811.
    2. Sound pressure level is the test average measured in a semi-anechoic chamber. The test position is 1m right in front of the unit for four sides and (1+H)/2m (where H is the height of the unit) above the floor. During in-situ operation, sound pressure levels may be higher as a result of ambient noise.
    3. If the unit is operating in the temperature range with Low temp mode, The antifreeze system must be used instead of the water system, and the antifreeze (especially the glycol solution) must meet the following two requirements at the same time:
      • Volume concentration ≥30%;
      • The freezing point temperature of antifreeze < the coldest temperature at the using site - 5.5°C; The dial code S1-2 needs to be set to ON. The inverter water pump needs to be matched, and the minimum water flow of the water pump should be able to be as low as 1.8 m3/h.
    4. If the unit is operating in the temperature range with High temp mode, the dial code S1-2 needs to be set to ON. The inverter water pump needs to be matched, and the minimum water flow of the water pump should be able to be as low as 1.8 m3/h.

    *It is recommended to customize the centralized drainage module if operating under ambient temperature -15°C.

    SeriesMARS
    TypeInverter
    Cooling Capacity50.00
    Heating Capacity50.00
    RefrigerantR290
    Noise Level54