Warning: Last items in stock!
Availability date:
Functions and extras:


















| Model | Indoor Unit | MA3-12HRDN8-QRD0GW | |
|---|---|---|---|
| Outdoor Unit | MA3-12HFN8-QRD0GW | ||
| Power Supply | V/O/Hz | 220-240 / 1 / 50 | |
| Capacity | Cooling | kW | 3.52 (1.11 - 4.16) |
| Heating | 3.81 (1.08 - 4.22) | ||
| Power Input | Cooling / Heating | kW | 0.13 - 1.58 / 0.10 - 1.68 |
| SEER | Cooling | W/W | 6.10 |
| SCOP | Heating | 4.00 | |
| Energy Efficiency Class | Cooling | A++ | |
| Heating (-7°C) | A+ | ||
| Running Current | Cooling/ Heating | A | 0.5 - 6.9 / 0.4 - 6.9 |
| Air Flow (indoor unit) | m3/h | 575 / 493 / 454 | |
| Sound Pressure (indoor unit) | dB(A) | 37.5 / 29 / 25 | |
| Sound Power (indoor unit) | dB(A) | 54 | |
| Air Flow (outdoor unit) | m3/h | 1800 | |
| Sound Pressure (outdoor unit) | dB(A) | 54 | |
| Sound Power (outdoor unit) | dB(A) | 64 | |
| Dimensions Wx H x D Weight | Indoor Unit | mm | 835 x 295 x 208 |
| kg | 8.4 | ||
| Outdoor Unit | mm | 720 x 495 x 270 | |
| kg | 23.2 | ||
| Refrigerant piping (liquid/gas) | mm | 6.35 / 9.52 | |
| Max. refrigerant pipe length | m | 25 | |
| Max. difference in level | 10 | ||
| Operation Temperature | Cooling | °C | -15 ~ 50 |
| Heating | -15 ~ 24 | ||
| Refrigerant / Charged (kg) | R32 / 0.55 | ||
The new Midea MA3-12HRDN8-QRD0GW Prime 2 inverter air conditioner has an A++/A+ (cooling/heating) energy efficiency class.
Compared to ordinary high-density dust filters, the high-density filter captures the finest dust particles in the air and provides up to 80% cleaner and healthier air.
The cold-catalyst filter eliminates formaldehyde and other volatile organic compounds (VOCs), as well as harmful gases and odors.
The i-Clean self-cleaning function uses an improved algorithm, upgrading the standard self-cleaning. iClean alternates between cooling and heating to freeze and defrost the indoor unit's heat exchanger, thus achieving much better cleaning and eliminating more pests. The i-Clean function lasts twice as long as a regular self-cleaning - about 30-35 minutes.
The low temperature kit allows air conditioning systems to operate in cooling mode at an outdoor temperature of -15°C.
The Golden Fin coating is more resistant to oxidation and corrosion than ordinary Blue Fin coating. Golden Fin effectively prevents the growth and spread of bacteria and improves resistance to corrosive elements.
The indoor unit of the air conditioner detects an error code "EC", which will be displayed and will stop working automatically when a freon leak is detected. This will protect the air conditioning compressor from damage caused by high temperatures when the refrigerant leaks. This function is only available in cooling mode.
In 8°C heating mode, this constant temperature is maintained, thus protecting the home from excessive cooling in winter or freezing of pipes and houseplants. The regime is especially suitable in the long absence of the occupants of the home.
When Turbo mode is activated, the indoor unit fan starts running at maximum speed to ensure the desired temperature as quickly as possible. The mode lasts a maximum of 20 minutes, after which it automatically returns to the preset mode before activating Turbo mode.
Horizontal louvers are floated at an angle of 120 °, while with conventional air conditioners this happens only at 90 °. These more flexible louvers provide cooling that is wider and more even.
This economy mode integrates a new innovative ECO energy saving technology. When the “ECO” button is activated, the air conditioner reduces energy consumption by 60% within 8 hours of continuous operation.
When night mode is activated during cooling, the air conditioner automatically raises the room temperature by 1 ° C for the first two hours, after which it remains fixed. When night mode is activated during heating, the air conditioner automatically lowers the room temperature by 1 ° C for the first two hours, after which it remains fixed.
The air conditioner automatically switches to power save mode when it is turned off (in Standby mode). This reduces power consumption from 5W to 1W, giving you up to 80% energy savings.
The drain pipe can be routed to the left and right side of the indoor unit of the air conditioner for easy and convenient installation.
In the event that the air conditioner stops working unexpectedly due to a power outage, it will restart automatically as soon as power is restored and will start operating in the mode set before the power was turned off.
Ability to set a 24-hour timer to turn the air conditioning system on and off within 24 hours.
The position of the horizontal valve of the air conditioning system is saved when switched off and is restored automatically when switched on again.
The indoor unit is compatible with both mono and multi inverter systems, allowing easy selection of suitable indoor and outdoor units. This is a convenient solution for warehouses and shopping centers.
| Type | Wall type air conditioners |
| Technology | Inverter |
| Series | Prime 2 |
| Indoor Unit | MA3-12HRDN8-QRD0GW |
| Outdoor Unit | MA3-12HFN8-QRD0GW |
| Power supply (V/ø/Hz) | 230 / 1 / 50 |
| Capacity (BTU) | 12000 Btu |
| Cooling Capacity (kW) | 3.52 (1.11 - 4.16) |
| Heating Capacity (kW) | 3.81 (1.08 - 4.22) |
| Power Input Cooling/Heating (kW) | 0.13 - 1.58 / 0.10 - 1.68 |
| SEER (Seasonal Cooling Efficiency) | 6.10 |
| SCOP (Seasonal Heating Efficiency) | 4.00 |
| Energy Efficiency Class (Cooling) | A++ |
| Energy Efficiency Class (Heating) | A+ |
| Current for Cooling / Heating (A) | 0.5 - 6.9 / 0.4 - 6.9 |
| Sound Pressure Indoor Unit - Cooling dB(A) | 37.5 / 29 / 25 |
| Sound Pressure Indoor Unit - Heating dB(A) | 37.5 / 29 / 25 |
| Sound Pressure Outdoor Unit - Cooling/Heating dB(A) | 54 / 54 |
| Sound Power Indoor Unit - Cooling/Heating dB(A) | 54 / 54 |
| Sound Power Outdoor Unit - Cooling/Heating dB(A) | 64 / 64 |
| Air Flow Indoor / Outdoor Unit - Cooling (m3/h) | 575 / 493 / 454 / 1800 |
| Dimensions - Indoor Unit WxHxD (mm) | 835 x 295 x 208 |
| Dimensions - Outdoor Unit WxHxD (mm) | 720 x 495 x 270 |
| Weight - Indoor Unit (kg) | 8.4 |
| Weight - Outdoor Unit (kg) | 23.2 |
| Piping Connections - Liquid/Gas (mm) | φ 6.35 / φ 9.52 |
| Maximum Pipe Lenght (m) | 25 |
| Maximum Height Difference (m) | 10 |
| Operation Range - Cooling (°C) | -15~50 |
| Operation Range - Heating (°C) | -15~24 |
| Refrigerant (type) | R32 |
| Refrigerant - factory charge (kg) | 0.55 |
| Warranty | 3 years |