Ceiling-floor air conditioner Midea MUE-55HRFNX-QRD0W / MOX630U-55HFN8RV1 | MIDEA.BG | Midea.bg
New Three-phase ceiling-floor type inverter air conditioner Midea MUE-55HRFNX-QRD0W

Three-phase ceiling-floor type inverter air conditioner Midea MUE-55HRFNX-QRD0W / MOX630U-55HFN8RV1

  • Type: Ceiling-floor type air conditioner;
  • Technology: Inverter air conditioner;
  • Energy Class: А++/A+;
  • Cooling SEER: 6.10;
  • Heating SCOP: 4.00;
  • Capacity: 55 000 Btu;
  • Warranty: 36 months.

VAT incl. price:

3 019,00 €

Find the nearest dealer

Functions and extras:

    Three-phase ceiling-floor type inverter air conditioner Midea MUE-55HRFNX-QRD0W

    The three-phase ceiling-floor type inverter air conditioner Midea MUE-55HRFNX-QRD0W achieves seasonal energy efficiency class A++ / A+ and has many intelligent features that will provide unforgettable comfort and coziness in every room. Thanks to its sleek design, the indoor unit fits into interiors of all kinds.

    Features and extras of the Midea MUE-55HRFNX-QRD0W three-phase inverter ceiling-floor air conditioner

    24-hour timer

    Ability to set a 24-hour timer to turn the air conditioning system on and off within 24 hours.

    Automatic restart

    In the event that the air conditioner stops working unexpectedly due to a power outage, it will restart automatically as soon as power is restored and will start operating in the mode set before the power was turned off.

    Turbo mode

    When Turbo mode is activated, the indoor unit fan starts running at maximum speed to ensure the desired temperature as quickly as possible. The mode lasts a maximum of 20 minutes, after which it automatically returns to the preset mode before activating Turbo mode.

    Fresh air inlet

    Outside air can be supplied through an additional ventilation duct. This ensures clean and fresh air in the air-conditioned room.

    Night mode

    When night mode is activated during cooling, the air conditioner automatically raises the room temperature by 1 ° C for the first two hours, after which it remains fixed. When night mode is activated during heating, the air conditioner automatically lowers the room temperature by 1 ° C for the first two hours, after which it remains fixed.

    Twin system

    The Twin system consists of two indoor units with different capacity from the same series connected to one outdoor unit.

    3D Airflow

    The louvers of the indoor unit of the air conditioner move automatically in all directions, ensuring even distribution of the air-conditioned air in all corners of the room.

    LCD display

    The indoor unit has a large LCD display giving information about the operation of the air conditioning system.

    Horizontal Swing

    Horizontal louvers are floated at an angle of 120 °, while with conventional air conditioners this happens only at 90 °. These more flexible louvers provide cooling that is wider and more even.

    Vertical Swing

    Vertical louvers float at an angle of 110 °, while with conventional air conditioners this happens only at 80 °. This results in cooling that is wider and more even.

    Alarm system port

    When a fault is detected in the air conditioning system, an external alarm system is activated, which signals an error and automatically stops its operation.

    Refrigerant leak detection

    The indoor unit of the air conditioner detects an error code "EC", which will be displayed and will stop working automatically when a freon leak is detected. This will protect the air conditioning compressor from damage caused by high temperatures when the refrigerant leaks.

    Two-way draining

    The drain pipe can be routed to the left and right side of the indoor unit of the air conditioner for easy and convenient installation.

    Easy maintenance and service

    The air conditioning system is specially optimized for easy maintenance and service.

    Louver memory

    The position of the horizontal valve of the air conditioning system is saved when switched off and is restored automatically when switched on again.

    Wired Control

    Wired controller can be fixed to the wall for a permanently mounted control solution.

    Central Management (optional)

    The central control is a multifunctional device that can control up to 64 indoor units with a maximum connection length of up to 1200 meters.

    TypeCeiling-floor type air conditioners
    TechnologyInverter
    Indoor UnitMUE-55HRFNX-QRD0W
    Outdoor UnitMOE30U-55HFN8-RRDOW(GA)
    Power supply (V/ø/Hz)400 / 3 / 50
    Capacity (BTU)55000 Btu
    Cooling Capacity (kW)15.83 (4.10 - 16.71)
    Heating Capacity (kW)18.17 (4.40 - 19.64)
    Power Input Cooling/Heating (kW)5.65 (1.10 - 6.65) / 6.05 (1.05 - 7.10)
    SEER (Seasonal Cooling Efficiency)6.10
    SCOP (Seasonal Heating Efficiency)4.00
    Energy Efficiency Class (Cooling)A++
    Energy Efficiency Class (Heating)A
    Current for Cooling / Heating (A)9.70 (3.20 - 11.50) / 10.50 (2.20 - 12.00)
    Sound Pressure Indoor Unit - Cooling dB(A)54 / 50.5 / 46.5 / 38
    Sound Pressure Indoor Unit - Heating dB(A)54 / 50.5 / 46.5 / 38
    Sound Pressure Outdoor Unit - Cooling/Heating dB(A)64 / 64
    Sound Power Indoor Unit - Cooling/Heating dB(A)67 / 67
    Sound Power Outdoor Unit - Cooling/Heating dB(A)75 / 75
    Air Flow Indoor / Outdoor Unit - Cooling (m3/h)2200 / 1950 / 1650 / 7500
    Dimensions - Indoor Unit WxHxD (mm)1650 x 235 x 675
    Dimensions - Outdoor Unit WxHxD (mm)980 x 975 x 375
    Weight - Indoor Unit (kg)42.3
    Weight - Outdoor Unit (kg)92
    Piping Connections - Liquid/Gas (mm)9.52 / 15.9
    Maximum Pipe Lenght (m)75
    Maximum Height Difference (m)30
    Operation Range - Cooling (°C)-15 ~ 50
    Operation Range - Heating (°C)-15 ~ 24
    Refrigerant (type)R32
    Refrigerant - factory charge (kg)3.00
    Warranty3 years