Functions and extras:
The R32 refrigerant has a low global warming potential (GWP=675) and zero ozone depletion potential (ODP), a high energy efficiency ratio, a low charge and working pressure, and is suitable for scenarios requiring efficient cooling and high safety.

All DC Inverter systems enable greater energy efficiency, more precise temperature control, lower noise and longer equipment life, providing a more comfortable and energy efficient use experience.

DC Inverter compressors can adjust the cooling capacity according to the actual demand, improving energy efficiency and reducing energy consumption.
DC Inverter fans can automatically adjust the wind speed according to changes in indoor temperature, providing a more comfortable environment and reducing noise.


DC Inverter pumps can adjust water flow according to system load changes, improve system efficiency and extend equipment life.
Water temperature automatically adjusts in response to ambient temperature to save energy.


Heat pump adjusts the operation according to different electrical signals. Power consumption of the system can be automatically adjusted according to the peak and valley power to reduce the power consumption to the greatest extent.
Users have the option to receive a customized energy analysis through the user interface, APP and portal, enabling intuitive, visual energy management which helps guide user behavior to achieve a more energy efficient heat pump system.
Complies with EU Regulations 2018/2001/EU and (EU) 2022/759 for the purpose of receiving subsidies.




SmartHome allows end users to control and monitor their heating system anytime, from anywhere.lts Compressor Capacity Calculation algorithm ensures precise monitoring of home energy usage for optimized performance. SmartHome APP supports access to Alexa and Google Home, and realizes voice control of the heat pump machine, which can be turned on and off, operation mode switch and temperature adjustment
Drying up mode is used to dry the floor after installation. Preheating mode is designed for the first heating during seasonal heating. The water temperature of floor heating loops would be increased gradually in order to protect the floor from warped or even rupture.


If user leaves, heat pump runs in heating mode and/or DHW mode with lower water temperature to prevent water system from freezing. Disinfection is available before user returns home to ensure the water security.
Flexible setting allow user to set a new schedule during the time at home but without changing the multiple daily or weekly setting.


The DHW pump function is used to return water in the water pipe net to the tank. Total 12 timers for one day can be set, which allows users to set the DHW pump operation schedule according to using habit to guarantee using hot water without waiting for a long time.
During the installation of the unit, the appropriate current usage is set in the Power Input Limitation function of the controller based on the user's power supply conditions. This ensures that the unit can operate safely and stably even when the power supply is limited.


The main control PCB of the unit has a port connected to the gateway, through the gateway to connect a number of temperature controllers, according to the needs of different heating areas to accurately adjust the temperature of each area.
A well-designed product should not only possess excellent performance but also focus on the quality of after-sales service to provide users with a seamless experience. By developing after-sales service tools and optimizing service processes, it ensures that after-sales personnel can efficiently resolve issues, thereby offering customers a superior service experience.


Easy for maintenance person to do the annual inspections.


M thermal Nature Plus is compatible with various terminals, including radiators, floor heating pipes, FCUs, and water tanks to meet the space heating, space cooling and domestic hot water needs of households. The high compatibility of our heat pumps allows them to work with other heat sources, such as solar energy systems, boilers, and electric heaters, to improve heating comfort.
Floor heating loops is used for space heating and fan coil unit is used for both space heating and cooling. For heating mode, floor heating loops and fan coil unit require different operating water temperature. Mixing station is used to adjust appropriate water temperature for floor heating loops using. 2-way valve is used to prevent water from entering floor heating loops then result in condensation during cooling.
Notes:


Backup electric heater(optional) and AHS provide additional heating to raise the leaving water temperature. TBH and solar system provide additional heating to raise the domestic hot water temperature. 3-way valve is used to switch between heating mode and DHW mode.
Notes:
Double zones control is only available for heating mode. It can control different areas to reach ifferent temperature to meet various needs.


Maximum 6 room thermostats are available to be connected with M-kit and 2 thermostats are connected to heat pump, which realizes maximum 8 rooms can be controlled.
| Technical Specifications for Midea M-Thermal Arctic Mono MHC-V6W/D2N8-B2Е30 Hreat Pump | ||||
|---|---|---|---|---|
| Model Name | MHC-V6W/D2N8-B2Е30 | |||
| Power Supply | V/Ph/Hz | 220-240/1/50 | ||
| Heating A7W35 | Capacity | kW | 6.35 | |
| Rated input | kW | 1.28 | ||
| COP | 4.95 | |||
| Heating A7W45 | Capacity | kW | 6.30 | |
| Rated input | kW | 1.70 | ||
| COP | 3.70 | |||
| Heating A7W55 | Capacity | kW | 6.00 | |
| Rated input | kW | 2.03 | ||
| COP | 2.95 | |||
| Heating A-7W35 | Capacity | kW | 6.00 | |
| Rated input | kW | 2.00 | ||
| COP | 3.00 | |||
| Heating A-7W55 | Capacity | kW | 5.15 | |
| Rated input | kW | 2.58 | ||
| COP | 2.00 | |||
| Cooling A35W18 | Capacity | kW | 6.50 | |
| Rated input | kW | 1.35 | ||
| EER | 4.80 | |||
| Cooling A35W7 | Capacity | kW | 7.00 | |
| Rated input | kW | 2.33 | ||
| EER | 3.00 | |||
| Seasonal space heating energy efficiency class | Water outlet at 35°C | A+++ | ||
| Water outlet at 55°C | A++ | |||
| SCOP | Warmer climate | 35°C | 6.57 | |
| 55°C | 4.21 | |||
| Average climate | 35°C | 4.95 | ||
| 55°C | 3.52 | |||
| Colder climate | 35°C | 4.21 | ||
| 55°C | 2.85 | |||
| SEER | Water outlet | 7°C | 5.31 | |
| 18°C | 8.22 | |||
| Sound power level 7 | dB | 58 | ||
| Rated water flow | m3/h | 1.09 | ||
| Water flow range | m3/h | 0.4 ~ 1.25 | ||
| Internal water volume | L | 2.16 ~ 6.96 | ||
| Compressor | Type | Twin rotary | ||
| Outdoor fan | Motor type / Number of fans | DC fan / 1 | ||
| Air side heat exchanger | Finned tube | |||
| Refrigerant / Charged quantity | R32 / 1.4kg | |||
| Net dimension (W x H x D) | mm | 1295 × 718 × 429 | ||
| Packing dimension (W x H x D) | mm | 1375 × 885 × 475 | ||
| Net / Gross weight | kg | 86 / 107 | ||
| Outdoor air temperature range | Cooling | °C | -5 ~ 43 | |
| Heating | °C | -25 ~ 35 | ||
| DHW | °C | -25 ~ 43 | ||
| Water side heat exchanger | Plate type | |||
| Water side connection | R1 " | |||
| LWT setting range | Cooling | °C | 5 ~ 25 | |
| Heating | °C | 25 ~ 65 | ||
| DHW | °C | 20 ~ 60 | ||
Notes:
| Series | M-Thermal Arctic Mono |
| Type | Inverter |
| Cooling Capacity | 7.00 |
| Heating Capacity | 6.35 |
| Refrigerant | R32 |