Our webstore uses cookies to offer a better user experience and we recommend you to accept their use to fully enjoy your navigation.
The new Midea MFAU-16HRFN8-QRD0W console inverter air conditioner has an A++/A (cooling/heating) energy efficiency class and compact and thin low-noise indoor unit with 2 air outlets and 4 air inlets. You can use both air outlets of the air conditioner or the upper one only.
When Turbo mode is activated, the indoor unit fan starts running at maximum speed to ensure the desired temperature as quickly as possible. The mode lasts a maximum of 20 minutes, after which it automatically returns to the preset mode before activating Turbo mode.
When night mode is activated during cooling, the air conditioner automatically raises the room temperature by 1 ° C for the first two hours, after which it remains fixed. When night mode is activated during heating, the air conditioner automatically lowers the room temperature by 1 ° C for the first two hours, after which it remains fixed.
The indoor unit fan runs at very low speeds, reducing noise and providing peace and quiet.
In the event that the air conditioner stops working unexpectedly due to a power outage, it will restart automatically as soon as power is restored and will start operating in the mode set before the power was turned off.
Ability to set a 24-hour timer to turn the air conditioning system on and off within 24 hours.
The fan speed in the indoor unit of the air conditioner is adjusted automatically depending on the temperature of the evaporator when heating the room. This prevents cold air from blowing when the air conditioner is started in heating mode.
The indoor unit of the air conditioner detects an error code "EC", which will be displayed and will stop working automatically when a freon leak is detected. This will protect the air conditioning compressor from damage caused by high temperatures when the refrigerant leaks.
The outdoor unit of the air conditioner can work in heating mode without problems at very low outdoor temperatures.
In the best air conditioners, when a sensor temperature error occurs, the system stops working. With Midea, the indoor unit reports an error code, but the system continues to operate in emergency mode.
In 8°C heating mode, this constant temperature is maintained, thus protecting the home from excessive cooling in winter or freezing of pipes and houseplants. The regime is especially suitable in the long absence of the occupants of the home.
The position of the horizontal valve of the air conditioning system is saved when switched off and is restored automatically when switched on again.
The indoor unit has a large LCD display giving information about the operation of the air conditioning system.
Model | Indoor Unit | MFAU-16HRFN8-QRD0W | |
---|---|---|---|
Outdoor Unit | MOX330U-18HFN8-QRD0W | ||
Power Supply | V/O/Hz | 220-240 / 1 / 50 | |
Capacity | Cooling | kW | 4.84 (2.64 - 5.13) |
Heating | 4.98 (2.20 - 5.24) | ||
Power Input | Cooling / Heating | kW | 1.60 (0.65 - 2.02) /1.54 (0.60 - 1.81) |
SEER | Cooling | W/W | 6.5 |
SCOP | Heating | 3.8 | |
Energy Efficiency Class | Cooling | A++ | |
Heating | A | ||
Running Current | Cooling/ Heating | A | 6.90 (2.95 - 8.90) / 6.83 (2.75 - 7.97) |
Air Flow (indoor unit) | m3/h | 560 / 480 / 400 | |
Sound Pressure (indoor unit) | dB(A) | 45 / 39 / 36 | |
Sound Power (indoor unit) | dB(A) | 60 | |
Air Flow (outdoor unit) | m3/h | 2100 | |
Sound Pressure (outdoor unit) | dB(A) | 56 | |
Sound Power (outdoor unit) | dB(A) | 65 | |
Dimentions W x D x H Weight |
Indoor Unit | mm | 700 x 210 x 600 |
kg | 14.7 | ||
Outdoor Unit | mm | 805 x 330 x 554 | |
kg | 32.5 | ||
Refrigerant piping (liquid/gas) | mm | 6.35 / 12.7 | |
Max. refrigerant pipe length | m | 30 | |
Max. difference in level | 20 | ||
Operation Temperature | Cooling | °C | -15 ~ 50 |
Heating | -15 ~ 24 | ||
Refrigerant | R32 |
Series | MFAU |
Type | Inverter |
Cooling Efficiency | A++ |
Heating Efficiency | A |
Cooling Capacity | 4.84 kW |
Heating Capacity | 4.98 kW |
Btu | 18000 Btu |